130 / 2024-04-14 15:37:16
DC Short-Circuit Current Transfer of Parallel Vacuum Switches with Different Intervals
vacuum switch,time intervals,DC circuit breaker
摘要录用
Li Li / Guangdong Power Grid Corp Electric Power Research Institute, Electric Power Research Institute of Guangdong Power Grid Co. LTD
Mingzhen Yang / Guangdong Power Grid Corp Electric Power Research Institute, Electric Power Research Institute of Guangdong Power Grid Co. LTD
Shuxing Ma / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
Qi Zhang / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
Bin Xiang / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
zhiyuan liu / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
Yingsan Geng / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
Jianhua Wang / State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi’an Jiaotong University
With the advancement of renewable energy source such as photovoltaic plant and wind farm, the capacity of DC grid is increasing rapidly. Larger grid capacity results in higher requirements of current load and interruption capacity in DC circuit breaker (DCCB). However, the capacity of single vacuum switch is limited to load several kiloampere system current. Parallel vacuum switches are needed to achieve higher load capacity. In this paper, to analyze the current transfer in parallel vacuum switches, a DC short-circuit experimental model is established with DCCB consisting of two parallel vacuum switches. The short-circuit current transfer between parallel vacuum switches and interruption characteristics of DCCB with different fault current and opening time intervals are investigated. From the experimental results, with the same opening time interval, higher short-circuit current results in longer current transfer time. With larger opening time interval, higher voltage in pre-charged capacitor is needed to interrupt the same fault current. In DC system with high load current, parallel vacuum switches can be used in DCCB with short opening time interval.
重要日期
  • 会议日期

    11月10日

    2024

    11月13日

    2024

  • 11月11日 2024

    初稿截稿日期

  • 11月19日 2024

    注册截止日期

主办单位
Xi’an Jiaotong Universit
历届会议
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询