207 / 2022-03-14 18:41:24
Effect of Surface Charge on Flashover Phenomena-A Dynamic Observation Using a 220 kV Cone Spacer
DC transmission, gas insulated transmission line, surface charge
终稿
Weijian Zhuang / Tsinghua University
Fangwei Liang / Tsinghua University
Zuodong Liang / Tsinghua University
Chuanjie Lin / Tsinghua University
Lingling Tang / Jiangsu Jinxin Electric Appliance Co. Ltd
Yulin Zeng / Jiangsu Jinxin Electric Appliance Co. Ltd
Bo Zhang / Tsinghua University
Chuanyang Li / Tsinghua University
Jinliang He / Tsinghua University
Purpose/Aim

The surface charge accumulation on spacers inside GIL distorts local surface electric field, which potentially triggers surface flashover. To study the effect of surface charge on flashover has great significance.

Experimental/Modeling methods

In this paper, the effect of surface charge properties on surface flashover voltage and arc path are studied using a 220 kV spacer subjected to operating overvoltage.

Results/discussion

1) The temporal and spatial correlation between surface charges and flashover characteristics of 220kV GIL under impulse voltage were directly observed for the first time. 2) The possibility of flashover is decreased when homopolar charges are accumulated on the 220 kV cone spacer, but increased when heteropolar charges are accumulated.

Conclusions

The arc motion using a 220 kV GIS spacer was studied.