Effects of Air Humidity and Hanging Angle on Accumulation Characteristics of Pollution Particles on Anti-icing Polymer Insulators
Anti-icing polymer insulator,Pollution particle,Accumulation characteristic,Hanging angle,Air humidity
终稿
Xianghuan Kong / School of Electrical and Information Engineering, Tianjin University
Yong Liu / School of Electrical and Information Engineering, Tianjin University
Tao Han / School of Electrical and Information Engineering, Tianjin University
Yu Gao / School of Electrical and Information Engineering, Tianjin University
Boxue Du / School of Electrical and Information Engineering, Tianjin University
Pollution flashover accident is one of the main faults in various high voltage transmission lines, which affects stability and safety of electrical power systems. The accumulation of pollution particles on the insulator surface is the premise of pollution flashover accidents. In this paper, based on the actual operating conditions of polymer insulators, suspension patterns of the insulator, movement trajectory of pollution particles and the air humidity were considered to investigate the accumulation characteristics of pollution particles by using FLUENT software. Firstly, according to the actual dimension of 500 kV anti-icing polymer insulators, the insulator simulation model and air flow field were established at a ratio of 1:1. Secondly, considering the influences of gravity and fluid drag force, pollution particles were added to the air flow field to analyze the motion characteristics of particles. Thirdly, the different hanging angles of “V” type insulator (15°,30°,45°,60°, -15°,-30°,-45°,-60°) and air humidity (0.01%, 0.04%, 0.07%, 0.1%) were set to study the collision rate of pollution particles. The pressure contour around the insulator, movement trajectory of pollution particles and collision rate were obtained with variation of air humidity and suspension patterns of the insulator. The obtained results show that with increasing the hanging angle of insulator, the collision rate of particles shows the increasing tendency from 0°~30°, but shows the decreasing tendency when the angle is higher than 30°. When the hanging angle is from 0° to -60°, the changing trends of collision rate is the same with that from 0° to 60°, but the maximum collision rate is smaller than that from 0° to 60°. As the humidity increases, the water vapor in the air prevents the movement of pollution particles, resulting in the decrease in the collision rate.
重要日期
  • 会议日期

    04月07日

    2019

    04月10日

    2019

  • 04月10日 2019

    注册截止日期

  • 05月12日 2019

    初稿截稿日期

主办单位
IEEE电介质和电气绝缘协会
中国电工学会工程电介质专业委员会
承办单位
华南理工大学
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询